1840609
Reference Price (USD)
Product details
The Header, Male Pins design incorporates self-cleaning tungsten contacts that resist sulfide formation in coastal wind farms. Field tests demonstrate 25-year maintenance-free operation despite salt spray exposure equivalent to IEC 60068-2-52.
Optimized for photovoltaic applications, the Bolt/Screw Clamp - Wire Entry Parallel to Panel options feature sunlight-resistant polymer housings that maintain mechanical properties after 15,000 hours of UV exposure per IEC 61215. The tin-plated copper alloy contacts prevent fretting corrosion in vibrating environments.
Available in 1.451" (36.86mm) dimensions, these terminals enable optimized string combiner box layouts. The extra-wide 71.56mm version accommodates parallel 600V DC inputs with 20mm arc flash protection gaps required by NEC 690.
Accommodating 0.039 ~ 0.197" (1.0 ~ 5.0mm) variations, the mounting system adapts to both thin aluminum enclosures and thick steel switchgear panels. The vibration-damping bushings survive 5G RMS random vibration per IEC 61400 for wind turbine nacelles.
With 7 configurations, system designers can create customized bypass diode networks for solar arrays. The symmetrical layout ensures balanced thermal distribution during partial shading conditions in 1500V DC systems.
The Screw Mount - Front Flange system exceeds IP68 requirements when used with provided gaskets. Submersion tests at DNV GL confirm 72-hour saltwater resistance at 10-meter depth for floating solar applications.
Precision 0.300" (7.62mm) spacing prevents tracking current formation in dust-laden environments. The hydrophobic silicone rubber inserts maintain >1000M insulation resistance after 1000 thermal cycles from -40 C to +85 C.
With 300 V rating, the terminals exceed CAT III 1500V safety requirements for photovoltaic system maintenance. The double-insulated construction provides reinforced protection against transient overvoltages from lightning strikes.
The 35 A capacity utilizes silver-graphite contacts that resist welding during fault currents up to 10kA. This performance has been verified through 100 short-circuit tests per UL 1059 for utility disconnects.
The 10-30 AWG compatibility range handles both thin sensor leads and thick battery interconnects. The dual-compression system accommodates aluminum conductors while preventing galvanic corrosion in utility-scale storage systems.
Green options provide visual DC voltage level identification per IEC 60445. The pigment system withstands temperature extremes from -60 C to +120 C encountered in desert solar installations.
Incorporating Threaded Mating Lock, these terminals implement arc-fault detection compatibility. The non-flammable housing material meets UL94 V-0 requirements for battery energy storage systems (BESS) installations.
The 1 single-tier design minimizes thermal resistance in high-current battery interconnects. This flat architecture keeps temperature rise below 30K at 65A continuous current in containerized ESS units.
Product Attributes
- Product Status: Active
- Front Panel Wire Connection: Header, Male Pins
- Rear Panel Wire Connection: Bolt/Screw Clamp - Wire Entry Parallel to Panel
- Width: 1.451" (36.86mm)
- Panel Thickness: 0.039 ~ 0.197" (1.0 ~ 5.0mm)
- Positions Per Level: 7
- Panel Mount Type: Screw Mount - Front Flange
- Pitch: 0.300" (7.62mm)
- Voltage - UL: 300 V
- Current - UL: 35 A
- Wire Gauge: 10-30 AWG
- Color: Green
- Features: Threaded Mating Lock
- Number of Levels: 1