3056941
Reference Price (USD)
Product details
The Push In Clamp - Wire Entry Angled to Panel system uses antimicrobial silver-ion impregnated contacts that reduce bacterial growth by 99.9% per ISO 22196. The smooth surfaces facilitate cleaning in OR environments while maintaining 10,000-cycle durability for movable C-arm connections.
Engineered for reliability, the Quick Connect - 0.250" (6.35mm) options feature ceramic-insulated feedthroughs that withstand 1000 autoclave cycles at 134 C. This meets AAMI ST8 requirements for steam sterilization in reusable medical devices.
With 0.319" (8.10mm) options available, designers can optimize space utilization in portable ultrasound machines. The ultra-compact 7mm version enables 30% smaller footprints while maintaining 4kV isolation for patient-connected circuits.
Compatible with 0.039 ~ 0.157" (1.0 ~ 4.0mm) variations, the mounts adapt to both thin composite housings and thick stainless steel panels. The conductive coating provides 360 RF shielding for sensitive biosignal amplifiers in patient monitors.
The 1 arrangement supports redundant safety circuits in life-support equipment. The mirrored contact design provides dual-path reliability for critical ventilator control signals without increasing panel space.
The 2 Piece incorporates radiopaque markers for X-ray equipment. The tungsten-loaded polymer housing provides clear imaging reference points while maintaining 50dB EMI shielding effectiveness per EN 60601-1-2 for MRI compatibility.
Rated for 300 V operation, the terminals exceed IEC 60601-1 defibrillation protection requirements. The arc-quenching channels safely dissipate 5kV test pulses without compromising adjacent circuits in crash carts.
The 30 A capacity utilizes medical-grade alloys that resist electrolytic corrosion in body fluid environments. Accelerated aging tests show <5% contact resistance change after 10 years simulated use in hospital-grade equipment.
Supporting 10-24 AWG ranges, these terminals handle both fine EEG electrode leads and heavy power cables. The dual-material strain relief prevents wire fatigue in mobile dialysis machines undergoing daily setup/teardown.
The Gray coding follows ISO 7010 safety standards for medical equipment. The non-absorbent surface finish resists staining from betadine and other antiseptics used in surgical environments.
Featuring Engagement Pin, these connectors implement single-fault tolerant designs per IEC 60601-1. The redundant locking mechanism prevents accidental disconnection during patient transport, meeting drop-test requirements for emergency equipment.
The 1 single-plane construction minimizes eddy current losses in RF ablation generators. This design reduces heating by 40% compared to stacked terminals during 500kHz electrosurgical procedures.
Product Attributes
- Product Status: Active
- Front Panel Wire Connection: Push In Clamp - Wire Entry Angled to Panel
- Rear Panel Wire Connection: Quick Connect - 0.250" (6.35mm)
- Width: 0.319" (8.10mm)
- Panel Thickness: 0.039 ~ 0.157" (1.0 ~ 4.0mm)
- Positions Per Level: 1
- Panel Mount Type: 2 Piece
- Pitch: -
- Voltage - UL: 300 V
- Current - UL: 30 A
- Wire Gauge: 10-24 AWG
- Color: Gray
- Features: Engagement Pin
- Number of Levels: 1