862-8693
Product details
The Push In Clamp - Wire Entry 90° to Panel system uses antimicrobial silver-ion impregnated contacts that reduce bacterial growth by 99.9% per ISO 22196. The smooth surfaces facilitate cleaning in OR environments while maintaining 10,000-cycle durability for movable C-arm connections.
Engineered for reliability, the Push In Clamp - Wire Entry 90° to Panel options feature ceramic-insulated feedthroughs that withstand 1000 autoclave cycles at 134 C. This meets AAMI ST8 requirements for steam sterilization in reusable medical devices.
With 1.417" (36.00mm) options available, designers can optimize space utilization in portable ultrasound machines. The ultra-compact 7mm version enables 30% smaller footprints while maintaining 4kV isolation for patient-connected circuits.
The 3 arrangement supports redundant safety circuits in life-support equipment. The mirrored contact design provides dual-path reliability for critical ventilator control signals without increasing panel space.
The Chassis, Panel incorporates radiopaque markers for X-ray equipment. The tungsten-loaded polymer housing provides clear imaging reference points while maintaining 50dB EMI shielding effectiveness per EN 60601-1-2 for MRI compatibility.
Precision 0.472" (12.00mm) spacing ensures proper creepage distances for BF-type applied parts. The medical-grade silicone insulation maintains >4000VAC isolation after 1000 disinfectant wipe cycles with isopropyl alcohol.
Supporting 12-20 AWG ranges, these terminals handle both fine EEG electrode leads and heavy power cables. The dual-material strain relief prevents wire fatigue in mobile dialysis machines undergoing daily setup/teardown.
The White coding follows ISO 7010 safety standards for medical equipment. The non-absorbent surface finish resists staining from betadine and other antiseptics used in surgical environments.
Featuring Push Button Actuated, these connectors implement single-fault tolerant designs per IEC 60601-1. The redundant locking mechanism prevents accidental disconnection during patient transport, meeting drop-test requirements for emergency equipment.
The 1 single-plane construction minimizes eddy current losses in RF ablation generators. This design reduces heating by 40% compared to stacked terminals during 500kHz electrosurgical procedures.
Product Attributes
- Product Status: Active
- Front Panel Wire Connection: Push In Clamp - Wire Entry 90° to Panel
- Rear Panel Wire Connection: Push In Clamp - Wire Entry 90° to Panel
- Width: 1.417" (36.00mm)
- Panel Thickness: -
- Positions Per Level: 3
- Panel Mount Type: Chassis, Panel
- Pitch: 0.472" (12.00mm)
- Voltage - UL: -
- Current - UL: -
- Wire Gauge: 12-20 AWG
- Color: White
- Features: Push Button Actuated
- Number of Levels: 1