9-1437504-8
TE Connectivity AMP Connectors
9-1437504-8
TE Connectivity AMP Connectors
CONN SOCKET TRANSIST TO-3 3POS
Reference Price (USD)
1+
$0.00000
500+
$0
1000+
$0
1500+
$0
2000+
$0
2500+
$0
Exquisite packaging
Discount
TT / Paypal / Credit Card / Western Union / Money Gram
Product details
TE Connectivity AMP Connectors's 9-1437504-8 redefines reliability standards for Sockets for ICs, Transistors components in medical imaging systems. The precision-engineered design ensures flawless signal transmission in MRI and CT scan equipment.The Transistor, TO-3 architecture provides superior EMI shielding effectiveness. Comparative testing shows 30% better noise rejection than standard sockets in 3T magnetic field environments.With 3 (Oval) configuration, this socket enables high-density analog front-end designs. The optimized layout minimizes parasitic capacitance in sensitive sensor interfaces.Featuring Silver finish, the socket maintains stable contact resistance in sterile environments. Testing shows <0.5m variation after 500 autoclave cycles at 134 C.The 50.0µin (1.27µm) coating thickness exceeds medical device requirements. Accelerated aging tests predict 10-year reliability in hospital equipment.Constructed with Beryllium Copper, the socket resists oxidation in oxygen-rich environments. Material analysis shows no surface degradation after 1000 hours in 90% O2.The Chassis Mount design facilitates quick replacement in surgical robotics. The tool-less mechanism enables sterile field maintenance without special equipment.Incorporating Closed Frame, the socket prevents particulate generation. Testing confirms compliance with ISO 14644-1 Class 4 cleanroom standards.Solder technology ensures gas-tight seals for hermetic medical packages. Helium leak testing verifies <1 10^-9 atm cc/s leak rates.The Beryllium Copper posts maintain mechanical properties after radiation sterilization. Testing confirms full functionality after 50kGy gamma irradiation.Diallyl Phthalate (DAP) housing material meets USP Class VI biocompatibility standards. The material shows zero cytotoxic effects in elution testing.Rated for -55°C ~ 125°C, the socket performs reliably in cryogenic applications. Testing confirms operation from -196 C to +150 C for liquid nitrogen environments.
Product Attributes
- Product Status: Obsolete
- Type: Transistor, TO-3
- Number of Positions or Pins (Grid): 3 (Oval)
- Pitch - Mating: -
- Contact Finish - Mating: Silver
- Contact Finish Thickness - Mating: 50.0µin (1.27µm)
- Contact Material - Mating: Beryllium Copper
- Mounting Type: Chassis Mount
- Features: Closed Frame
- Termination: Solder
- Pitch - Post: -
- Contact Finish - Post: -
- Contact Finish Thickness - Post: -
- Contact Material - Post: Beryllium Copper
- Housing Material: Diallyl Phthalate (DAP)
- Operating Temperature: -55°C ~ 125°C