ECHP381V-08P
Product details
The Header, Male Pins system uses antimicrobial silver-ion impregnated contacts that reduce bacterial growth by 99.9% per ISO 22196. The smooth surfaces facilitate cleaning in OR environments while maintaining 10,000-cycle durability for movable C-arm connections.
Engineered for reliability, the Quick Connect - 0.114" (2.90mm), Solder Eyelet options feature ceramic-insulated feedthroughs that withstand 1000 autoclave cycles at 134 C. This meets AAMI ST8 requirements for steam sterilization in reusable medical devices.
Compatible with 0.020 ~ 0.157" (0.5 ~ 4.0mm) variations, the mounts adapt to both thin composite housings and thick stainless steel panels. The conductive coating provides 360 RF shielding for sensitive biosignal amplifiers in patient monitors.
The 8 arrangement supports redundant safety circuits in life-support equipment. The mirrored contact design provides dual-path reliability for critical ventilator control signals without increasing panel space.
The Screw Mount - Front Flange incorporates radiopaque markers for X-ray equipment. The tungsten-loaded polymer housing provides clear imaging reference points while maintaining 50dB EMI shielding effectiveness per EN 60601-1-2 for MRI compatibility.
Precision 0.150" (3.81mm) spacing ensures proper creepage distances for BF-type applied parts. The medical-grade silicone insulation maintains >4000VAC isolation after 1000 disinfectant wipe cycles with isopropyl alcohol.
Rated for 300 V operation, the terminals exceed IEC 60601-1 defibrillation protection requirements. The arc-quenching channels safely dissipate 5kV test pulses without compromising adjacent circuits in crash carts.
The 8 A capacity utilizes medical-grade alloys that resist electrolytic corrosion in body fluid environments. Accelerated aging tests show <5% contact resistance change after 10 years simulated use in hospital-grade equipment.
The Green coding follows ISO 7010 safety standards for medical equipment. The non-absorbent surface finish resists staining from betadine and other antiseptics used in surgical environments.
The 1 single-plane construction minimizes eddy current losses in RF ablation generators. This design reduces heating by 40% compared to stacked terminals during 500kHz electrosurgical procedures.
Product Attributes
- Product Status: Active
- Front Panel Wire Connection: Header, Male Pins
- Rear Panel Wire Connection: Quick Connect - 0.114" (2.90mm), Solder Eyelet
- Width: -
- Panel Thickness: 0.020 ~ 0.157" (0.5 ~ 4.0mm)
- Positions Per Level: 8
- Panel Mount Type: Screw Mount - Front Flange
- Pitch: 0.150" (3.81mm)
- Voltage - UL: 300 V
- Current - UL: 8 A
- Wire Gauge: -
- Color: Green
- Features: -
- Number of Levels: 1