Laird Thermal Systems, Inc.'s 387005514 represents the pinnacle of thermal management technology for Thermal - Thermoelectric, Peltier Modules in medical applications. Designed for patient-critical equipment, this Peltier module offers fail-safe operation and precise temperature control for MRI systems, laboratory analyzers, and portable medical devices.<p>The medical-grade Square - 20.00mm L x 20.00mm W dimensions comply with healthcare equipment standards while providing optimal thermal transfer for sensitive components.</p><p>With 19.4W @ 27°C heat transfer capacity, the module maintains critical temperature stability for life-saving medical equipment.</p><p>The 73.6°C @ 27°C maximum temperature differential enables precise control of diagnostic equipment operating temperatures.</p><p>The 3.50mm profile has been optimized for medical equipment designs where space is at a premium.</p><p>The 1-stage architecture provides redundant cooling paths for fail-safe operation in medical applications.</p><p>Medical-grade reliability ensures stable operation at 4 A for 24/7 healthcare environments.</p><p>The 8.3 V voltage rating accommodates both mains-powered and battery-operated medical devices.</p><p>Precision-controlled 1.94 Ohms ensures consistent performance across all medical operating conditions.</p><p>Certified for 120°C operation, the module meets stringent medical equipment requirements.</p><p>Medical-specific Lead Wires, Sealed - Silicone RTV include biocompatible materials and sterilization compatibility.</p>
Product Attributes
- Product Status: Active
- Size / Dimension: Square - 20.00mm L x 20.00mm W
- Qmax @ Th: 19.4W @ 27°C
- Delta Tmax @ Th: 73.6°C @ 27°C
- Height: 3.50mm
- Number of Stages: 1
- Current - Max: 4 A
- Voltage - Max: 8.3 V
- Resistance: 1.94 Ohms
- Operating Temperature: 120°C
- Features: Lead Wires, Sealed - Silicone RTV